Communicate with Supplier? Supplier
Richard Mr. Richard
What can I do for you?
Contact Supplier
ZSL MED

ZSL MED

zslmed@digitrex.com.cn

86-755-23253102

ZSL MED
HomeProductsCOVID-19 ProductsVTM Disposable Virus Sampling Kit10-in-1 VTM virus sampling kit
10-in-1 VTM virus sampling kit
10-in-1 VTM virus sampling kit
10-in-1 VTM virus sampling kit
10-in-1 VTM virus sampling kit
  • 10-in-1 VTM virus sampling kit
  • 10-in-1 VTM virus sampling kit
  • 10-in-1 VTM virus sampling kit
  • 10-in-1 VTM virus sampling kit

10-in-1 VTM virus sampling kit

    Payment Type: L/C,T/T,Western Union
    Incoterm: FOB,CFR,CIF,EXW,FCA,CPT,CIP
    Min. Order: 100 Piece/Pieces
    Delivery Time: 1 Days

Basic Info

Model No.: 10-in-1 sampling tube

Type: Vacuum Blood Tube & Blood Bag

Material: Plastic

Certification: CE

Ethylene Oxide Sterilization: Without Ethylene Oxide Sterilization

Quality Guarantee Period: Two Years

Additional Info

Packaging: pouch/box/carton

Productivity: 100K/day

Brand: Poweray

Transportation: Ocean,Land,Air

Place of Origin: PR CHINA

Supply Ability: 100M/month

HS Code: 3926909090

Port: ,,

Product Description


product name

Common name: 10-in-1 disposable Virus Sampling Tube

Packing specifications

Model: Non-Inactivated

Specification: 10-in-1, 6mL/pc; 50pcs/box

Intended use

For the collection and delivery of clinical virus samples.

Principle

The solution in the inactivated sampling tube contains guanidine salts and other components, which can quickly cleave the virus to release nucleic acids and prevent nucleic acid degradation .


Non-inactive Virus Transportation Medium


[Main components]

---

Storage conditions and expiration date

Store at 2 30 ℃ in a dark place and dry place. Valid period is 12 months

Applicable Instruments

No special instrument is required for the operation of this sampling tube .

[Sample requirements]

1. Samples should be transported to the laboratory for testing immediately after collection ; if they cannot be delivered immediately , they should be stored at -70 ℃ or below and sent to the laboratory for testing within one week .

2. The sample should avoid repeated freezing and thawing .

Testing method

1. According to the sampling requirements, use a sampling swab to collect samples;

2. Place the sampling swab after collecting the sample into the sampling tube;

3. Break the swab at the easy break point of the sampling swab rod and discard the tail;

4. Tighten the sampling tube cover;

5. Mark the information on the sampling tube label as required .

Product Performance Index

1. Appearance

Inactivated: tube should be no damage and no leakage, the inner tube solution is orange or orange- red, clear liquid .

2. Loading

The volume of the tube should not be less than the indicated value.

3. pH value

Inactivated: when 25 ℃, pH value should be 6.5 ± 0. . 3 .

4. Difference between batches

Randomly draw three sampling tubes of different batch numbers to test the pH value, and the results should meet the requirements under the pH value item.

5 . Stability

To random sample within one month lifetime , were detected from 1 to 3, the result should comply with the requirements of 1 to 3 .

[Limitations of detection methods]

1. Samples must be collected following the clinically recommended sample collection guidelines .

2. Repeated freezing and thawing of samples may reduce the recovery rate of living organisms.

3. The virus sampling tube is only used for the collection and transportation of virus samples.

4. poly propylene or nylon flocked swab for specimen collection.

5. This product should be used in combination with Rapid Diagnostic kits or diagnostic instruments.

Precautions

1. This product is only used for in vitro diagnostics, for use by qualified personnel properly trained , before use should carefully read the instructions and follow carefully .

2. Each serving is for one person, for one-time use. Do not use it on more than one patient. Repeated use may lead to infection and/or inaccurate risks.

3. The sample may have microbiological risks, so when handling all items, the standard protection requirements of the medical institution should be followed.

4. After use, sterilize all biohazardous wastes (including samples, containers and media, etc.).

5. Do not re-sterilize unused swabs, the swabs are obviously damaged, please do not use.

6. It is forbidden to directly contact the sampling liquid with the person being collected, and it is forbidden to soak the swab with the sampling liquid before sampling .

7. Products that have expired or the product packaging is damaged shall not be used.

8. When the samples are tested, they should be operated in a laboratory that meets the safety level.

References

1. National Influenza Surveillance Technical Guide (2017 edition) .

2. Influenza A H1N1 Influenza Surveillance Plan (Second Edition) .

3. WHO global influenza network surveillance program .

Looking for ideal 10-in-1 VTM Virus Sampling Manufacturer & supplier ? We have a wide selection at great prices to help you get creative. All the Covid 19 Testing Saliva Collection Tube are quality guaranteed. We are China Origin Factory of Massive Virus Screening Medical Checkup. If you have any question, please feel free to contact us.

Product Categories : COVID-19 Products > VTM Disposable Virus Sampling Kit

Email to this supplier
  • RichardMr. Richard
  • Your message must be between 20-8000 characters

Related Products List

Home

Phone

About Us

Inquiry